Grab latest EMC E20-393 Dumps as PDF Updated on 2022
Newly Released E20-393 Dumps for EMCIE Certified
Dell EMC Unity Solutions Specialist Exam Certification Details:
| Sample Questions | Dell EMC Unity Solutions Specialist Sample Questions |
| Schedule Exam | Pearson VUE |
| Exam Code | E20-393 |
| Exam Price | $230 (USD) |
| Passing Score | 63% |
| Books / Training | Dell EMC Unity Concepts and Features – On-Demand Course (ES131STG00107) Dell EMC Unity XT Hardware Concepts and Features - On-Demand Course (ES131STG01194) Dell EMC Unity Installation and Service - On-Demand Course (ES132STG00109) Dell EMC Unity Implementation and Administration – Classroom (ES112STG00110) |
NEW QUESTION 144
The soft limit quota for a file system has just been exceeded. What would you expect to occur concerning data
access?
- A. If the soft limit remains exceeded and the grace period expires, no new data may be added to the
particular file system or directory. - B. Once the soft limit is reached, the grace period counts down until the hard limit is reached. New data can
be written as long as the hard limit has not been reached. - C. If the soft limit remains exceeded and the grace period expires, new data may be added to the particular
directory. The system will alert the grace period expired. - D. Once the soft limit is reached, no new data can be added to the file system or directory.
Answer: B
NEW QUESTION 145
A system administrator is browsing their local management station for a Unity license file. Which file extension is used for Unity license files?
- A. .lic
- B. .cer
- C. .rsa
- D. .ulf
Answer: D
NEW QUESTION 146
What block size do Dell EMC Unity systems use to copy highly accessed blocks of data from spinning drives
into FAST Cache?
- A. 32 KB
- B. 16 KB
- C. 128 KB
- D. 64 KB
Answer: D
NEW QUESTION 147
A Unity 400 system has Data at Rest Encryption licensed and enabled. Which operation(s) must be performed from the Unisphere Settings window to ensure the system is still operational after SP replacements?
- A. Download Checksum
- B. Download Audit Log
- C. Download Audit Log and Checksum
- D. Backup Keystore File
Answer: D
Explanation:
Explanation/Reference:
The keystore is tied to the storage processors, so care must be taken when performing service operations in order to preserve the encryption keys. In the event that the chassis and both storage processors need to be replaced, both storage processors should not be replaced at the same time. Instead, the chassis replacement should be followed while retaining one SP until the array is back online before replacing the second SP. In the case that storage processors have already been replaced at the same time and the keystore was lost, the keystore may be restored from an external backup.
NEW QUESTION 148
Which information must be retrieved and used to select the unconfigured UnityVSA system when running the Auto-discover option of the Connection Utility?
- A. System's UUID
- B. Array Name
- C. System's Serial ID
- D. DNS Host Name
Answer: C
Explanation:
Note: The Connection Utility can be use the Auto Discover option to discover the system and configure the system name, IPv4 management settings, and/or IPv6 management settings.
References:
https://www.emc.com/collateral/TechnicalDocument/docu69316.pdf
NEW QUESTION 149
A company plans to add five drives to a 30 drive SAS Flash 4 All-Flash pool on a Dell EMC Unity
600 storage array. Which drive type(s) can be used for the expansion?
- A. SAS Flash 4 only
- B. SAS Flash 3 and SAS Flash 4 only
- C. SAS Flash 2 and SAS Flash 4 only
- D. Any SAS Flash drive type
Answer: D
NEW QUESTION 150
A storage administrator wants to create a series of daily snapshots for an existing critical LUN. How can the snapshots be created?
- A. From the LUN Properties page, configure the Snapshot schedule
- B. Snapshot schedules can only be configured within the LUN Creation wizard
- C. From the Pool Properties page, configure the Snapshot schedule
- D. Only manually taken snapshots are supported on existing LUNs
Answer: C
Explanation:
Explanation/Reference:
In addition to being created ahead of time on the Snapshot Schedules page, new snapshots schedules may also be created during the process of creating a new storage resource from within the creation wizard as an alternative to selecting an existing schedule.
Incorrect Answers:
C: In addition to being taken manually, snapshots can also be scheduled to be taken automatically at specific times or frequencies.
NEW QUESTION 151
A storage administrator is replicating a NAS Server from one Dell EMC Unity to another. The destination system has a different network scheme than their source system.
What operation must be done on the destination system NAS Server to ensure data is accessible after failover?
- A. Change the Override properties
- B. Create a new interface
- C. Modify DNS Cache
- D. No changes required
Answer: A
Explanation:
Explanation/Reference: https://www.dellemc.com/es-ve/documentation/unity-family/unity-p-replication-config/01-unity-rep- br-overview.htm
NEW QUESTION 152
A system administrator wants to grant privileges to manage storage resources and host configurations for some users. However, the administrator wants to ensure users have no privileges to manage user accounts, change network settings and NAS servers, or perform software upgrades. Which user role should be associated with the user accounts to be created?
- A. Service
- B. Operator
- C. Administrator
- D. Storage Administrator
Answer: A
NEW QUESTION 153
What is a consideration when attempting to downgrade from Integrated ESRS Two-way to ESRS One-way?
- A. Ensure that port 9443 is open
- B. Validate Dell EMC Support Credentials
- C. Downgrading ESRS is not supported
- D. Run readiness check prior to downgrading ESRS
Answer: C
NEW QUESTION 154
A service provider is installing a Unity storage system for an end-user. The end-user is concerned about network security and will not allow the service provider access to the network.
How can the service provider set a static IP address for the Unity storage system management interface?
- A. Connect directly to the service ports and configure the networking through UEMCLI
- B. Use the Connection Utility to create a configuration file
- C. Use the embedded InitCLI tool
- D. Use an IPMI serial over LAN connection
Answer: B
Explanation:
Explanation
When setting up the system, and a network connection cannot be used, use the Unity Connection Utility to create a configuration file. Save the file to an usb drive, and put the drive into the usb port of the SP Using UEMCLI requires an ip address to the system, thus accessing the network to change the IP address. But therefore the system must already be accessible from the network. Which in this case is not allowed.
NEW QUESTION 155
Which IP connection characteristic is unique to file-based storage access, as opposed to iSCSI?
- A. Mirrored writes
- B. Bandwidth throttle
- C. Link Aggregation
- D. VLAN tagging
Answer: C
NEW QUESTION 156
A storage administrator wants to create a series of daily snapshots for an existing critical LUN. How can the snapshots be created?
- A. From the LUN Properties page, configure the Snapshot schedule
- B. Snapshot schedules can only be configured within the LUN Creation wizard
- C. From the Pool Properties page, configure the Snapshot schedule
- D. Only manually taken snapshots are supported on existing LUNs
Answer: C
Explanation:
In addition to being created ahead of time on the Snapshot Schedules page, new snapshots schedules may also be created during the process of creating a new storage resource from within the creation wizard as an alternative to selecting an existing schedule.
Incorrect Answers:
C: In addition to being taken manually, snapshots can also be scheduled to be taken automatically at specific times or frequencies.
NEW QUESTION 157
A system administrator has configured a Unity storage system using the Initial Configuration wizard. After completing the wizard, the administrator discovers that an incorrect IP address has been assigned to the Unity system. How can the IP address be changed?
- A. Inthe Unisphere Settings menu
- B. The IP address can only be changed using the UEMCLI
- C. The IP address cannot be changed once it has been configured
- D. Through the Service interface using the ifconfig command
Answer: B
NEW QUESTION 158
What is the minimum VMware Hypervisor version a server must be running in order to support the deployment of a UnityVSA system?
- A. 5.0
- B. 6.0
- C. 4.0
- D. 5.5
Answer: D
Explanation:
UnityVSA requirements include: VMWare ESXi 5.x, 6.x
References:
https://sweden.emc.com/products-solutions/trial-software-download/unity-vsa.htm
NEW QUESTION 159
Which task must be performed on the storage system in order to access a file system read/write snapshot?
- A. Configure Host Access to the LUN snapshots
- B. Perform the snapshot "Attach to Host" operation
- C. Connect to the NFS/SMB share of the snapshot
- D. Configure the NFS/SMB share to the file system snapshot
Answer: D
Explanation:
Explanation
Read-write snapshots can be made available to hosts as separate shares.
The Shared property is applicable to file snapshots only, and indicates whether the snapshot is currently available to clients as a share. The default value is No, and changes to Yes when the read-write file system snapshot is used to create shares. For read-only file system snapshots, this property is always set to No.
Share - A named, mountable instance of file-level storage, accessible through a file system or VMware NFS Datastore. Each share is accessible through the protocol (NFS or SMB) defined for the file system where it resides.
NEW QUESTION 160
......
Details like Exam Cost, Questions, and Time Duration
The E20-393 aspirants should kick start the test preparation journey by knowing the exam and its details well. This way, the voyage becomes easy and achievable. So, next is the facts that one should accumulate about E20-393. In particular, the Dell EMC E20-393 exam is 90 minutes long and includes 60 items. The vendor hasn’t provided any information about the types of questions that will show up in the actual exam. However, the most general question format that the majority of certification exams follow is MCQ, case study, and performance-based. As for the passing percentage, it is 63%. When an expense is a matter of concern, be ready to spend $230 per attempt for E20-393. This amount has to be paid towards the exam voucher, which is neither transferable nor refundable. To complete the test registration procedure, one has to visit the Pearson VUE official website. Commonly, this platform carries the responsibility to conduct different exams across the world via online and offline proctoring. In both the options, E20-393 will be computer-based and is stored digitally. Test-takers can find out the pass or fail status soon after the final exam. However, one has to wait for three working days to obtain a full score report.
EMC E20-393 Exam Syllabus Topics:
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
| Topic 6 |
|
| Topic 7 |
|
| Topic 8 |
|
Latest E20-393 Exam Dumps EMC Exam from Training: https://www.certkingdompdf.com/E20-393-latest-certkingdom-dumps.html